WM97+ CT Wall Mount Gas Boiler

Models: WM97+ 70 CT, WM97+ 110 CT, WM97+ 155 CT

Saves TIME, Saves MONEY

  • Class-Leading High Efficiency Wall Mount Boiler
  • Built-in Pre-Installed System Components
  • Advanced Controls for Flexible Cost-Saving Operations

Key Features

  • 70,000; 110,000 & 155,000 BTU input models at 95% AFUE
  • Stylish, compact wall mount design for easy installation, service and maintenance
  • Unique condensing stainless steel fire tube heat exchanger design
  • Built-in boiler circulator
  • Built-in primary/secondary piping option
  • Pre-wired terminal strip for quick and easy electrical connections
  • Convenient indirect-fired water heater connection
  • Capable to vent with PVC, PP and SS up to 100′
  • Multi-color LCD display with text – no codes
  • CT – Condensing Technology – 5 to 1 turndown ratio
  • Aqua Logic indirect fired water heater compatible
Model*
Input MBH DOE Heating Capacity MBH Net I=B=R Water Ratings MBH DOE Seasonal Efficiency AFUE % Vent Diameter Inches Vent Material Boiler Water Content Gal.
Max Min
WM 97+ 70 CT 70 14 65 57 95.2 3 PVC, CPVC, PP, SS 2.8
WM 97+ 110 CT 110 22 101 88 95.0 3 PVC, CPVC, PP, SS 2.8
WM 97+ 155 CT 155 28 143 124 95.1 3 PVC, CPVC, PP**, SS 3.4

*Natural gas field convertible to LP as standard equipment

** Requires Centrotherm SS concentric termination 

Ultra Gas S3 CT Gas Boiler 

Models: UG-80, UG-105, UG-155, UG-230, UG-299, UG-399


Boiler Intelligence for Every Heating Need

  • Optimal Efficiency for Multiple Temperatures
  • Quick System Presets to Match any Application
  • Seamless Multiple Boiler Control

Features

  • Gas fired water boiler with cast aluminum heat exchanger
  • Venturi mixing body mixes air and gas providing higher efficiency
  • Designed to operate in low temperature condensing applications
  • Outdoor reset and domestic hot water priority standard
  • Negative regulated gas valve precisely delivers gas to the boiler
  • U-Control gives you the power for easy set-up and maintenance
  • Modulates with 5 to 1 turn-down ratio
  • Variable speed motor matches combustion output to heating needs
  • High grade stainless steel burner features quiet operation, high efficiency, and cleaner combustion for low NOx applications
Model A.G.A. Input (MBH) DOE Heating Capacity (MBH) Net I=B=R Ratings (MBH) Min. Vent Size Annual Fuel Utilization Efficiency (AFUE)
UG-80 80 71 62 2 or 3 in. PVC/CPVC 93.5%
UG-105 105 94 81 2 or 3 in. PVC/CPVC 94.0%
UG-155 155 139 123 3 in. PVC/CPVC 94.0%
UG-230 230 207 183 3 or 4 in. PVC/CPVC 94.1%
UG-299 299 270 234 4 in. PVC/CPVC 92.5%
UG-399 399 365* 317 4 in. PVC/CPVC 91.7%*

*Combustion Efficiency

Sentinel X100 Water Treatment included with boiler 
Click here for more information on Sentinel products 

CGa Gas Boiler Series 1 and Series 2

Atmospheric Gas Boiler (Water)

Models: CGa-25, CGa-3, CGa-4, CGa-5, CGa-6, CGa-7, CGa-8

Features

  • Compact design saves valuable living space
  • Stainless steel burners for quieter ignition, longer life, and improved combustion
  • Gas fired water boiler with cast iron sections
  • Easily accessible controls, vertical flueways and top cleaning for easy and quick servicing
  • Up to 84% AFUE 

Series 1

Model A.G.A. Input (MBH) PIDN AFUE SPDN AFUE SPDL AFUE DOE Heating Capacity (MBH) Net I=B=R Ratings (MBH) Min. Chimney Size
CGa-25 52 84.0 81.5 83.3 44 38 4″ x 20′
CGa-3 70 84.0 81.6 83.7 59 51 4″ x 20′
CGa-4 105 84.0 81.7 83.7 88 77 5″ x 20′
CGa-5 140 83.5 81.8 83.7 117 102 6″ x 20′
CGa-6 175 83.2 81.9 83.6 146 127 6″ x 20′
CGa-7 210 83.0 82.0 83.6 175 152 7″ x 20′
CGa-8 245 82.7 82.1 83.6 204 177 7″ x 20′
CGa Brochure Series 1 (1.0MB)

Series 2

Model A.G.A. Input (MBH) PIDN 
AFUE
DOE Heating Capacity (MBH) Net I=B=R Ratings (MBH) Min. Chimney Size
CGa-25 52 84.0 44 38 4″ x 20′
CGa-3 70 84.0 59 51 4″ x 20′
CGa-4 105 84.0 88 77 5″ x 20′
CGa-5 140 83.5 117 102 6″ x 20′
CGa-6 175 83.2 146 127 6″ x 20′
CGa-7 210 83.0 175 152 7″ x 20′
CGa-8 245 82.7 204 177 7″ x 20′

CGa Brochure Series 2 (1.0MB) 

CGi Gas Boiler Series 2 and Series 3

High Efficiency Gas, Induced Draft Boiler (Water)

Models CGi-25, CGi-3, CGi-4E, CGi-4, CGi-5, CGi-6, CGi-7, CGi-8

Features

  • Gas fired water boiler with cast iron sections
  • Natural draft and direct exhaust capability
  • Can be used with natural or propane gas
  • All units are factory-tested
  • Compact design saves valuable living space
  • No vertical draft hood and no mechanical vent damper
  • Intermittent electronic ignition with standard components for easy servicing
  • Up tp 85% AFUE

Series 2

Model A.G.A. Input (MBH) DOE Heating Capacity (MBH) Net I=B=R Ratings (MBH) Min. Vent Size Annual Fuel Utilization Efficiency (AFUE)
CGi-25 50 42 37 4″ 84.0
CGi-3 60 51 45 4″ 85.1
CGi-4 100 85 74 5″ 84.0
CGi-5 120 100 87 5″ 83.3
CGi-6 167 140 122 5″ 83.3
CGi-7 200 167 145 5″ 83.0
CGi-8 233 194 169 5″ 82.7
CGi-4E 90 76 66 5″ 85.0
CGi Brochure Series 2 (1.1MB)

Series 3

Model A.G.A. Input (MBH) DOE Heating Capacity (MBH) Net I=B=R Ratings (MBH) Min. Vent Size Annual Fuel Utilization Efficiency (AFUE)
CGi-25 50 42 37 4″ 84.0
CGi-3 60 51 45 4″ 85.1
CGi-4 90 76 66 5″ 85.0
CGi-5 120 100 87 5″ 83.3
CGi-6 167 140 122 5″ 83.3
CGi-7 200 167 145 5″ 83.0
CGi-8 233 194 169 5″ 82.7
CGi Brochure Series 3 (882KB)

 

CGt Gas Boiler

High Efficiency Gas, Tankless Heater (Water)

Models: CGt-PIN

Features

  • The CGt is available in one size and has a built-in tankless heater as standard equipment.
  • The CGt gas boiler from Weil-McLain offers a compact design boiler that also provides domestic hot water.
  • Other features include high-grade stainless steel burners, integrated control module and venting flexibility.81% AFUE
Model A.G.A. Input (MBH) DOE Heating Capacity (MBH) Net I=B=R Ratings (MBH) Min. Chimney Size Annual Fuel Utilization Efficiency (AFUE)
CGt-PIN 133 108 94 3″ 81.0

CGt Brochure (1.0MB)

EG Gas Water & Steam Boilers 

Features:

  • Comes with automatic vent damper for higher efficiencies and reduced fuel consumption
  • Easy access to controls for convenient servicing
  • Available with standing pilot or intermittent electronic ignition alt=”http://www.weil-mclain.com/en/images/lrg31_60553671x386_WM_EG_boiler.jpg” class=”decoded” data-mce-src=”http://www.weil-mclain.com/en/images/lrg31_60553671x386_WM_EG_boiler.jpg” data-mce-style=”float: right;” v:shapes=”_x0000_i1032″>
  • A versatile gas cast iron boiler for water or steam applications
  • Cast iron heat exchanger
  • Up to 84% AFUE
Model A.G.A. Input (MBH) PIDN SPDN SPDL DOE Heating Capacity (MBH) Net I=B=R Ratings (MBH) Min. Chimney Size
EG-30 Steam 75 83.0 81.0 82.6 62 47 5″ x 20′
EG-30 Water 75 84.3 82.2 84.2 62 55 5″ x 20′
EG-35 Steam 100 82.9 81.3 82.5 83 62 5″ x 20′
EG-35 Water 100 83.6 82.0 83.7 83 73 5″ x 20′
EG-40 Steam 125 82.9 81.5 83.2 104 78 6″ x 20′
EG-40 Water 125 84.0 82.5 84.3 104 91 6″ x 20′
EG-45 Steam 150 82.9 81.6 83.0 125 94 6″ x 20′
EG-45 Water 150 83.5 82.4 84.0 125 110 6″ x 20′
EG-50 Steam 175 82.8 81.9 83.7 145 109 7″ x 20′
EG-50 Water 175 83.8 82.9 84.4 145 128 7″ x 20′
EG-55 Steam 200 82.8 81.9 83.5 167 125 7″ x 20′
EG-55 Water 200 83.8 82.5 84.2 167 146 7″ x 20′
EG-65 Steam 250 83.0 82.0 82.8 209 157 8″ x 20′
EG-65 Water 250 84.0 82.6 84.0 209 183 8″ x 20′
EG-75 Steam 300 0.0 0.0 0.0 240 180 8″ x 20′
EG-75 Water 300 0.0 0.0 0.0 240 209 8″ x 20′
EG Brochure (1.1MB)

 

ECO Wall Mount Gas Boiler

Models: ECO 70, ECO 110, ECO 155

Features

  • Class-leading 70,000, 110,000, and 155,000 BTUH models
  • Exceeds Energy Star requirements at 95% AFUE efficiency rating
  • Durable stainless steel fire tube heat exchanger
  • Streamlined design configurable for installation
  • Display can be mounted on the boiler or wall (up to 2’ away)
  • Components positioned for fast and easy service
  • Multiple vent configurations and material options
  • Optional accessories to match virtually any installation
Model* Input MBH DOE Heating Capacity MBH Net I=B=R Water Ratings MBH DOE Seasonal Efficiency AFUE % Vent Diameter Inches Vent Material Boiler Water Content Gal.
Max Min
ECO 70 70 14 65 57 95.2 3 PVC, CPVC, PP, SS 2.5
ECO 110 110 22 101 88 95.0 3 PVC, CPVC, PP, SS 2.5
ECO 155 155 28 143 124 95.1 3 PVC, CPVC, PP, SS 3.2

*Natural gas field convertible to LP as standard equipment 

GV90+ Gas Boiler

Model GV90+3, GV90+4, GV90+5, GV90+6


High Efficiency Gas, Power Vented Boiler (Water)

Features

  • 91% AFUE efficient
  • Durable cast iron primary heat exchanger
  • Condensing stainless steel secondary heat exchanger
  • Unique 7 pass heat exchanger design maximizes heat transfer
  • Vents with PVC
  • Multiple vention options (direct vent, direct exhaust, concentric)
  • Easy conversion to propane (kit included)
Model A.G.A. Input (MBH) DOE Heating Capacity (MBH) Net I=B=R Ratings (MBH) Min. Vent Size Annual Fuel Utilization Efficiency (AFUE)
GV90+3 70 65 56 3″ 91.9
GV90+4 105 97 84 3″ 91.2
GV90+5 140 130 113 3″ 91.4
GV90+6 175 161 140 3″ 91.0
GV90+ Brochure (1.5MB)

 

Dieter Heating and Air Conditioning
4815 S Canfield Niles Rd
Canfield OH  44406
Phone: 330-533-4363
Fax: 330-533-4327

 

 

Brands

Rheem

 

 

Products

Furnaces, Air Conditioners, Water Heaters, Thermostats, Mini Splits, Heat Pumps, Air Cleaners, Humidifiers, Garage Heaters

 

 

Areas Serviced

Canfield, Youngstown & the Tri-County area